01.120.0201B Masonry wall intersecting concrete wall

This detail shows a grouted, reinforced, single wythe concrete masonry wall intersecting a cast in place concrete wall. Horizontal bars are hooked 90° and overlap adjacent horizontal bars a minimum of 40 bar diameters or 24 inches in the masonry, or as designed; the same hooks extend 12" into the concrete, or as designed. Open end conventional concrete masonry units and open end bond beam units are used throughout. This detail as shown is intended to illustrate a general concept or method of construction. Details that show different or modified concepts or methods can be of equal validity and should not be excluded from consideration. this detail shall not be used for construction without the approval an signature of a licensed design professional. The person using this detail shall be responsible for its complete design and proper application.

Comments

Popular posts from this blog

10.030.0633 Lintel rebuild | Terra cotta, extruded

10.030.0433 Sill and mullion rebuild | Terra cotta, extruded

06.EJ171.F Tile expansion joint | Floor movement joint, generic