02.120.0216 Wall restraint parallel to deck

This detail shows the top of wall restraints where the corrugated decking runs parallel to the masonry wall. Angles on both sides of the wall are welded to a steel plate, which is anchored to the bottom of the flutes of the decking above. The angles are secured to the masonry with self tapping screws. The top of the masonry is held back about 1 1/2" from the plate above. This detail as shown is intended to illustrate a general concept or method of construction. Details that show different or modified concepts or methods can be of equal validity and should not be excluded from consideration. this detail shall not be used for construction without the approval an signature of a licensed design professional. The person using this detail shall be responsible for its complete design and proper application.

Comments

Popular posts from this blog

01.030.0332 Base of Wall | Anchored Brick Veneer, CMU Backing, CMU Foundation

02.120.0215 Grout pour at top of concrete masonry wall

10.030.0733 Cornice and parapet rebuild | Terra cotta, extruded