06.EJ171.F Tile expansion joint | Floor movement joint, generic

Expansion joints in the field of tile floors are essential and required in order to accommodate building movements and to prohibit cracks in the substrate from telegraphing to the tile finish. This detail illustrates a generic movement joint in tile installed over a concrete floor with a cementitious bond coat. Bond breaker tape over the concrete prevents three-sided adhesion of the sealant. Joint width, location, and frequency of field expansion joints are as specified by the design professional. Sealant type shall be specified by design professional and shall be compatible with other components in the system. This detail is based on Tile Council of North America (TCNA) method EJ171F. Details that show different or modified concepts or methods can be of equal validity and should not be excluded from consideration. this detail shall not be used for construction without the approval an signature of a licensed design professional. The person using this detail shall be responsible for its complete design and proper application.

Comments

Popular posts from this blog

10.030.0633 Lintel rebuild | Terra cotta, extruded

10.030.0433 Sill and mullion rebuild | Terra cotta, extruded